Chilled water piping and ductwork in a commercial mechanical room

Senoia, Georgia · Serving the Southeast since 1994

Precision HVAC Testing, Adjusting & Balancing.

Our highly trained and experienced TAB technicians have been providing professional, accurate, reliable Test, Adjusting and Balancing using state-of-the-art, calibrated instrumentation since 1994.

NEBB — National Environmental Balancing Bureau
Certified
1 yr
Guaranty
100%
Independent

Services

Total System Balance

Total System Balance is the process of Testing, Adjusting and Balancing HVAC systems and subsystems to perform at the design intent and operate at the optimum level. The process includes a review of the design documents, construction observation and a methodical approach that yields verifiable results.

Air Balance

Measuring and adjusting the air flow of an HVAC system, resulting in proper operation and overall space comfort for the occupants.

Water Balance

Measuring and adjusting water flow through hot and chilled water coils to provide, together with air balancing, overall space comfort.

Ultrasonic Water Balance

A non-intrusive method of balancing water systems using ultrasonic technology when balancing ports or circuit setters aren't available.

Duct Pressure Testing

Testing the amount of air leakage in a specified duct in order to identify and minimize leakage for optimum system performance.

OR & Isolation Room Testing

Balancing operating rooms, isolation rooms and other medical areas so air changes and pressure relationships comply with current regulations.

Clean Room Balancing

Balancing clean rooms to the engineer's design specifications to achieve intended air changes, pressure relationships and ISO classifications.

Fume Hood Testing

Verifying face velocities and containment performance of laboratory fume hoods to keep personnel and processes safe.

Retro-Commissioning

Diagnosing comfort and humidity problems in existing buildings. The cause is often a negatively pressurized building envelope, hydronic problems, or simply poor air distribution — we test the systems, find the root cause and recommend the fix.

Annual Health Care Room Testing

Test and verify the pressures and Air Changes per Hour (ACH) for critical rooms in health care facilities following ANSI/ASHRAE/ASHE Standard 170-2021.

Operating room with laminar flow ceiling diffusersCompounding pharmacy cleanroom with a laminar flow hood and HEPA ceiling filtersCentral chiller plant with hydronic piping, pumps and an outdoor cooling tower

Why Georgia Balance

Guarantees consistently provided to you

Independence

We specialize exclusively in Testing, Adjusting and Balancing, with no affiliation or alliance with manufacturers or contractors.

Guaranty

All projects performed by Georgia Balance Co. are guaranteed for a period of one year.

Instrumentation

We submit a list of the instruments used, with calibration dates, on all projects.

Certification

Our trained personnel deliver TAB services in accordance with NEBB and the highest standards in the industry.

Reports

Comprehensive reports with a table of contents, all technical data for the systems specified, and recommendations where necessary.

Inspection

An open invitation to review readings and verify report contents upon completion of every project.

Support

We discuss, review and clarify any questions the client may have on any project.

All projects are performed by Georgia Balance Co. technicians, then reviewed and approved by a Georgia Balance NEBB Certified Professional (CP).

About us

Thirty years of doing it the right way

Founded in July 1994 by George Skouteris and Stephen Garner, Georgia Balance has delivered precise test and balance services for more than three decades. After 20 years as partners, Stephen Garner retired in May 2013.

In 2023, Santiago Gallo and Alexia Skouteris acquired the company. Under their leadership, the firm remains committed to the same core principles that defined it from the start: excellence, performance, accuracy, and outstanding customer service. Every technician is trained to uphold these standards.

Today Georgia Balance continues to operate with experienced leadership while integrating new technologies that deliver faster, more accurate results for clients—always guided by the ethics and craftsmanship established in 1994.

Leadership

Experienced, certified leadership

George Skouteris

Founder

35+ years of air and hydronic test and balance experience. NEBB CP.

Santiago Gallo

President

7 years of experience. NEBB CP.

Alexia Skouteris

Vice President

What our customers are saying

Trusted by hospitals, contractors and facility teams

GBC has been doing our annual pressurization test for 4 years. I could not ask for a company that is more reliable and easier to work with. When he is checking air flows, if there is a problem, he will stop and repair before he goes on to the next room. That is a great piece of mind — when the report arrives it is a finished document without a lot of problems that need addressed.
Herman M. MotesDirector of Engineering, East Georgia Regional Medical Center
Our facility has been using Georgia Balance for 10 plus years and have always found them to be professional and knowledgeable. They are always helpful in identifying a problem and coming to a solution to get the result we need.
Gary SnyderFacilities Lead Tech, Piedmont Newnan Hospital

Employment Opportunities

We’re always looking for technicians with integrity who take pride in going the extra mile to get the job done right.

If that sounds like you, send us your resume and we’ll be in touch.

Apply Now